Test stand for regulating magnet

Rotary Table
Station 1: Manual mounting and removal
Station 2: Reserve
Station 3: Preliminary examination
Station 4: Leak test
Station 5: Characteristic curve check
Station 6: Gauging the contacting pins for straightness
Station 7: Marking
Station 8: Reserve

Checks:

  • Checking the coil inductance
  • Checking the coil resistance
  • Test of high voltage
  • Leak test
  • Measuring the plunger paths
  • Recording of the current path characteristic curve in the supply and return flow

The recording of the current path characteristic curve takes place via a current ramp (WM signal with programmed current ramp and frequency). The magnetic plunger is extended against a spring with a matched characteristic curve.

Marking:
Needle scriber

Control:
Industrial PC with subordinated SPS

Production location:
USA